DESCRIPTION/SPECIFICATION
Operating Voltage Range - 180-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 6 KVA
Max. Operating Current - 27 A (@180V)
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous
DESCRIPTION/SPECIFICATION
Operating Voltage Range - 180-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 12.5 KVA
Max. Operating Current - 56 A (@180V)
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous
DESCRIPTION/SPECIFICATION
Operating Voltage Range - 200-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 24 KVA (8 KVA Per Phase)
Max. Operating Current - 40 A (@180V) Per Phase
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V Per Phase
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous
DESCRIPTION/SPECIFICATION
Operating Voltage Range - 180-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 12.5 KVA
Max. Operating Current - 56 A (@180V)
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous
DESCRIPTION/SPECIFICATION
Operating Voltage Range - 200-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 11 KVA (3.6 KVA Per Phase)
Max. Operating Current - 17 A (@180V) Per Phase
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V Per Phase
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous
DESCRIPTION/SPECIFICATION
Operating Voltage Range - 180-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 18 KVA
Max. Operating Current - 80 A (@180V)
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous
DESCRIPTION/SPECIFICATION
Operating Voltage Range - 200-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 18 KVA (6 KVA Per Phase)
Max. Operating Current - 27 A (@180V) Per Phase
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V Per Phase
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous
DESCRIPTION/SPECIFICATION
Operating Voltage Range - 200-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 30 KVA (10 KVA Per Phase)
Max. Operating Current - 47 A (@180V) Per Phase
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V Per Phase
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous
DESCRIPTION/SPECIFICATION
Operating Voltage Range - 200-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 37.5 KVA (12.5 KVA Per Phase)
Max. Operating Current - 56 A (@180V) Per Phase
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V Per Phase
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous
DESCRIPTION/SPECIFICATION
Operating Voltage Range - 200-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 60 KVA (20 KVA Per Phase)
Max. Operating Current - 85 A (@180V) Per Phase
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V Per Phase
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous
DESCRIPTION/SPECIFICATION
Operating Voltage Range - 200-260V AC Per Phase
Operating Frequency - 48 Hz - 62 Hz
KVA Rating (Max) - 60 KVA (20 KVA Per Phase)
Max. Operating Current - 85 A (@180V) Per Phase
Cooling - Air (Natural/Forced)
Max. on State Voltage drop - 2.5V Per Phase
Operating Ambient Temp. - 5*C - 50*C
Sensing Time - 2 mS - 4mS
Operating Frequency - 10 mS
Max Signaling Time - 20 mS
Max. Switching Time - <3.5%
Degree of Protection - IP 31
Turn Ratio - Customized
Duty Cycle - Continuous